Home >> Problema >> Electrodomésticos >> Acondicionadores de aire >> Dometic

Duo-Therm BriskAir 13.5k + horno Hydroflame 8531-IV: termostato no da 12V a cable azul horno

Duo-Therm BriskAir 13.5k controla horno Hydroflame 8531-IV: cable azul termostato sin 12V

Termostato Dometic controla A/C y horno. Horno no enciende. Cable azul (terminal W típicamente) sin 12V. Puente 12V a cable azul → horno funciona. Termostato nuevo → igual. Click en unidad A/C al poner calor.

Diagnóstico: relé horno en caja control techo

"Look at control box in roof unit, usually use separate wire set for furnace. See what colors connected to harness to thermostat. Some just go to other harness, out to thermostat. (Bypass control box) Once determined which 2, jumper them & see if furnace starts. If yes → thermostat bad. If no → pull roof cover & verify voltages at furnace."

Pasos sistemáticos

  1. Quite cubierta techo → caja control (donde convergen cables).
  2. Identifique arnés hacia termostato: ¿qué colores van a horno? (Típico: azul = W, rojo = R, blanco = C).
  3. Puente directo en caja control: una los 2 cables horno (R + W / azul) → ¿horno arranca?
  4. Si SÍ → termostato o cableado termostato-caja malo.
  5. Si NO → quite cubierta exterior horno (rejilla retorno interior) → localice 2 cables azules → una directamente → ¿horno arranca?
  6. Verifique voltaje horno: 12 V o 24 V (según modelo horno). Parque modelo → posible 24 V.