Lista completa para **GLTF2940ES** y modelos Affinity/Gallery similares:
| Código | Significado / Condición de fallo |
|---|---|
| E11 | Fill time too long (llenado lento) |
| E13 | Water leak in tub or air leak in air bell |
| E14 | Reed switch (interruptor de nivel) |
| E21 | Drain not pumping fast enough |
| E23 | Drain pump relay on control board failed |
| E24 | Drain pump relay on control board failed |
| E31 | Pressure sensor not communicating with control board (better models) |
| E35 | Pressure sensor indicates overfill (better models) |
| E41 | Control thinks door switch is open |
| E42 | Door remains locked after cycle ends (control board issue) |
| E43-E46 | Control board problems |
| E47 | Control thinks door PTC circuit open in spin |
| E48 | Control thinks door PTC circuit closed |
| E52 | Bad tachometer signal / motor overheating |
| E55 | Motor overheating |
| E56 | High motor current |
| E57 | High inverter current |
| E58 | High motor phase current |
| E59 | No tach signal for 3 seconds |
| E5A-E5C | High heatsink temperature |
| E5D-E5F | Communication problem |
| E67 | Incorrect input voltage to microprocessor |
| E75 | Water temp sensor circuit (better models) |
| E76 | NTC temp for cold water valve out of limits (better models) |
| E95 | Communication error |
| EB1 | Incoming power frequency out of limits |
| EB2 | Incoming line voltage > 130 VAC |
| EB3 | Incoming line voltage < 90 VAC |
| EF1 | Clogged drain pump |
| EF2 | Excessive soap (too much detergent) |
**Primero: Reset 10 min** (borra falsos). Si código persiste → busca en tabla → **técnico** para confirmar y reparar pieza indicada.